{"title":"NTS Series","description":null,"products":[{"product_id":"mean-well-nts-2200-112us-true-sine-wave-dc-ac-inverter-2200w-110v-out-12v-in-with-us-socket","title":"Mean Well NTS-2200-112US True Sine Wave DC-AC Inverter 2200W 110V out 12V in with US Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh surge power up to 4400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load dissipation \u0026lt; 1.7W at standby saving mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicator for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery over-discharge protection(Low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProtection type: Shut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC O\/P:3.0KVAC AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, UL62368-1, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS En\/EN61000-4-2,3,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pcs \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":45027690348829,"sku":"NTS-2200-112US","price":789.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/f6e151cfa4838cc47c8d5549288686d446231bde_NTS_2200_112US_11_f7eb40af-1161-4d91-9b81-54d25842e3be.jpg?v=1772349938"},{"product_id":"mean-well-nts-2200-124us-true-sine-wave-dc-ac-inverter-2200w-110v-out-24v-in-with-us-socket","title":"Mean Well NTS-2200-124US True Sine Wave DC-AC Inverter 2200W 110V out 24V in with US Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh surge power up to 4400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load dissipation \u0026lt; 1.7W at standby saving mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicator for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery over-discharge protection(Low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProtection type: Shut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC O\/P:3.0KVAC AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, UL62368-1, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS En\/EN61000-4-2,3,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pcs \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":45027691069725,"sku":"NTS-2200-124US","price":789.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/5359f7308d0263f5e905eb0a6f76b345a84213f5_NTS_2200_124US_11_63573e95-5b10-42e3-a4d2-c3763a780fed.jpg?v=1772349952"},{"product_id":"mean-well-nts-2200-148us-true-sine-wave-dc-ac-inverter-2200w-110v-out-48v-in-with-us-socket","title":"Mean Well NTS-2200-148US True Sine Wave DC-AC Inverter 2200W 110V out 48V in with US Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh surge power up to 4400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load dissipation \u0026lt; 1.7W at standby saving mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicator for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery over-discharge protection(Low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProtection type: Shut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC O\/P:3.0KVAC AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, UL62368-1, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS En\/EN61000-4-2,3,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pcs \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":45027691692317,"sku":"NTS-2200-148US","price":789.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/3942ccd71127b65a65177440ae1e8ccbdb11427a_NTS_2200_148US_11_49468685-9d19-4d0e-ab92-be95270f7d2c.jpg?v=1772349966"},{"product_id":"mean-well-nts-250p-212-true-sine-wave-dc-ac-inverter-250w-230v-out-12v-in","title":"Mean Well NTS-250P-212 True Sine Wave DC-AC Inverter 250W 230V out 12V in","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCompact size and lightweight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFanless design, cooling by free air convention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load disspation \u0026lt; 1.5W max. at standby saving mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-20℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery over-discharge protection (Low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport Tx\/Rx for monitoring power inverter status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC O\/P:3.0KVAC AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 for all models; E13, EAC TPTC004, AS\/NZS 62368.1 for NTS-250P-212\/224\/248 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS En\/EN61000-4-2,3,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186x100.5x32mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18pcs \/ 14.5Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":45027692249373,"sku":"NTS-250P-212","price":95.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/faa5cc146d57bdb9b255b613dbdfe122e458bac1_NTS_250P_212_main_9b0411a7-b1a6-4f2a-a3da-834f7eeb8c39.jpg?v=1775769341"},{"product_id":"mean-well-nts-250p-224-true-sine-wave-dc-ac-inverter-250w-230v-out-24v-in","title":"Mean Well NTS-250P-224 True Sine Wave DC-AC Inverter 250W 230V out 24V in","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCompact size and lightweight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFanless design, cooling by free air convention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load disspation \u0026lt; 1.5W max. at standby saving mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-20℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery over-discharge protection (Low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport Tx\/Rx for monitoring power inverter status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC O\/P:3.0KVAC AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 for all models; E13, EAC TPTC004, AS\/NZS 62368.1 for NTS-250P-212\/224\/248 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS En\/EN61000-4-2,3,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186x100.5x32mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18pcs \/ 14.5Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":45027693101341,"sku":"NTS-250P-224","price":95.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/027ebf836686c9d8ce49e24d71170579139a932d_NTS_250P_224_main_ff6d13d9-a0f2-4fa6-b9ba-f09207d755d4.jpg?v=1775769350"},{"product_id":"mean-well-nts-250p-248-true-sine-wave-dc-ac-inverter-250w-230v-out-48v-in","title":"Mean Well NTS-250P-248 True Sine Wave DC-AC Inverter 250W 230V out 48V in","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCompact size and lightweight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFanless design, cooling by free air convention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load disspation \u0026lt; 1.5W max. at standby saving mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-20℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery over-discharge protection (Low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport Tx\/Rx for monitoring power inverter status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC O\/P:3.0KVAC AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 for all models; E13, EAC TPTC004, AS\/NZS 62368.1 for NTS-250P-212\/224\/248 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS En\/EN61000-4-2,3,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186x100.5x32mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18pcs \/ 14.5Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":45027693756701,"sku":"NTS-250P-248","price":95.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/941d8700deb7beb9fbf7d1fa8532d608a3c30c48_NTS_250P_248_main_884a9eb7-5607-47d9-9cce-1624f02aca79.jpg?v=1775769360"},{"product_id":"mean-well-nts-400p-212-true-sine-wave-dc-ac-inverter-400w-230v-out-12v-in","title":"Mean Well NTS-400P-212 True Sine Wave DC-AC Inverter 400W 230V out 12V in","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCompact size and lightweight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh surge power up to 800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250W convection, 400W forced air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load disspation \u0026lt; 1.5W max. at standby saving mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery over-discharge protection(Low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport Tx \/ Rx for monitoring power inverter status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC O\/P:3.0KVAC AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 for all models; E13, EAC TPTC004, AS\/NZS 62368.1 for NTS-400P-212\/224\/248 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS En\/EN61000-4-2,3,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186x100.5x32mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18pcs \/ 14.5Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":45027698213149,"sku":"NTS-400P-212","price":108.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/67b091dd810671b40efe1b1e0d17ec2752eac881_NTS_400P_212_main_5fbb9a41-7f32-4a2e-8fb8-3e9c18da3bcf.jpg?v=1775769370"},{"product_id":"mean-well-nts-400p-224-true-sine-wave-dc-ac-inverter-400w-230v-out-24v-in","title":"Mean Well NTS-400P-224 True Sine Wave DC-AC Inverter 400W 230V out 24V in","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCompact size and lightweight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh surge power up to 800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250W convection, 400W forced air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load disspation \u0026lt; 1.5W max. at standby saving mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery over-discharge protection(Low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport Tx \/ Rx for monitoring power inverter status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC O\/P:3.0KVAC AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 for all models; E13, EAC TPTC004, AS\/NZS 62368.1 for NTS-400P-212\/224\/248 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS En\/EN61000-4-2,3,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186x100.5x32mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18pcs \/ 14.5Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":45027698639133,"sku":"NTS-400P-224","price":106.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/94c6119a40c954f1ad9437b624325e9098bf7a8d_NTS_400P_224_main_e2e33a44-acc6-4055-89f7-b7997a8614be.jpg?v=1775769380"},{"product_id":"mean-well-nts-400p-248-true-sine-wave-dc-ac-inverter-400w-230v-out-48v-in","title":"Mean Well NTS-400P-248 True Sine Wave DC-AC Inverter 400W 230V out 48V in","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCompact size and lightweight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh surge power up to 800W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250W convection, 400W forced air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load disspation \u0026lt; 1.5W max. at standby saving mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery over-discharge protection(Low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport Tx \/ Rx for monitoring power inverter status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC O\/P:3.0KVAC AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 for all models; E13, EAC TPTC004, AS\/NZS 62368.1 for NTS-400P-212\/224\/248 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS En\/EN61000-4-2,3,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e186x100.5x32mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18pcs \/ 14.5Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":45027699294493,"sku":"NTS-400P-248","price":108.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/f261f0fbcdeaab41dc01552b728848b69e514e84_NTS_400P_248_main_f5359d72-ec83-4892-a682-65f12dea1201.jpg?v=1775769390"},{"product_id":"mean-well-ntu-1200-112us-true-sine-wave-dc-ac-inverter-1200w-110v-out-12v-in-with-us-socket","title":"Mean Well NTU-1200-112US True Sine Wave DC-AC Inverter 1200W 110V out 12V in with US Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 2000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 approved, Design refer to AS\/NZS 62368.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e333x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 7.6Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250274504989,"sku":"NTU-1200-112US","price":315.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-1200-112us-true-sine-wave-dc-ac-inverter-1200w-110v-out-12v-in-with-us-socket-4768552.jpg?v=1777117751"},{"product_id":"mean-well-ntu-1200-124us-true-sine-wave-dc-ac-inverter-1200w-110v-out-24v-in-with-us-socket","title":"Mean Well NTU-1200-124US True Sine Wave DC-AC Inverter 1200W 110V out 24V in with US Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 2000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 approved, Design refer to AS\/NZS 62368.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e333x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 7.6Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250276307229,"sku":"NTU-1200-124US","price":315.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/376ec7c381edb77494743aa30b5d99666c53f006_NTU_1200_124US_main.jpg?v=1775769407"},{"product_id":"mean-well-ntu-1200-148us-true-sine-wave-dc-ac-inverter-1200w-110v-out-48v-in-with-us-socket","title":"Mean Well NTU-1200-148US True Sine Wave DC-AC Inverter 1200W 110V out 48V in with US Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 2000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 approved, Design refer to AS\/NZS 62368.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e333x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 7.6Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250278273309,"sku":"NTU-1200-148US","price":315.52,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/69b57071ff8feef601ff49191443c19f2cbbe86b_NTU_1200_148US.jpg?v=1775769415"},{"product_id":"mean-well-ntu-1200-212au-true-sine-wave-dc-ac-inverter-1200w-200v-out-12v-in-with-au-socket","title":"Mean Well NTU-1200-212AU True Sine Wave DC-AC Inverter 1200W 200V out 12V in with AU Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 2000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 approved, Design refer to AS\/NZS 62368.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e333x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 7.6Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250279944477,"sku":"NTU-1200-212AU","price":338.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-1200-212au-true-sine-wave-dc-ac-inverter-1200w-200v-out-12v-in-with-au-socket-1373540.jpg?v=1777117751"},{"product_id":"mean-well-ntu-1200-224au-true-sine-wave-dc-ac-inverter-1200w-220v-out-24v-in-with-au-socket","title":"Mean Well NTU-1200-224AU True Sine Wave DC-AC Inverter 1200W 220V out 24V in with AU Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 2000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 approved, Design refer to AS\/NZS 62368.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e333x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 7.6Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250281189661,"sku":"NTU-1200-224AU","price":338.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/f61e38bc73d627ebf80094c5b0fd9708b957cb4b_NTU_1200_224AU.jpg?v=1775769431"},{"product_id":"mean-well-ntu-1200-248au-true-sine-wave-dc-ac-inverter-1200w-220v-out-48v-in-with-au-socket","title":"Mean Well NTU-1200-248AU True Sine Wave DC-AC Inverter 1200W 220V out 48V in with AU Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 2000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1 approved, Design refer to AS\/NZS 62368.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e333x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 7.6Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250281419037,"sku":"NTU-1200-248AU","price":338.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-1200-248au-true-sine-wave-dc-ac-inverter-1200w-220v-out-48v-in-with-au-socket-9938580.jpg?v=1777117751"},{"product_id":"mean-well-ntu-1700-112us-true-sine-wave-dc-ac-inverter-1700w-110v-out-12v-in-with-us-socket-with-ac-by-pass-function","title":"Mean Well NTU-1700-112US True Sine Wave DC-AC Inverter 1700W 110V out 12V in with US Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 3400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 12Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250282303773,"sku":"NTU-1700-112US","price":436.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-1700-112us-true-sine-wave-dc-ac-inverter-1700w-110v-out-12v-in-with-us-socket-with-ac-by-pass-function-5269889.jpg?v=1777117751"},{"product_id":"mean-well-ntu-1700-124us-true-sine-wave-dc-ac-inverter-1700w-110v-out-24v-in-with-us-socket-with-ac-by-pass-function","title":"Mean Well NTU-1700-124US True Sine Wave DC-AC Inverter 1700W 110V out 24V in with US Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 3400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 12Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250282402077,"sku":"NTU-1700-124US","price":436.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/5cfafbed12d1561153eb25d6b8a04071618e02f1_NTU_1200_124US.jpg?v=1775769456"},{"product_id":"mean-well-ntu-1700-148us-true-sine-wave-dc-ac-inverter-1700w-110v-out-48v-in-with-us-socket-with-ac-by-pass-function","title":"Mean Well NTU-1700-148US True Sine Wave DC-AC Inverter 1700W 110V out 48V in with US Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 3400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 12Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250282565917,"sku":"NTU-1700-148US","price":436.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-1700-148us-true-sine-wave-dc-ac-inverter-1700w-110v-out-48v-in-with-us-socket-with-ac-by-pass-function-3411721.jpg?v=1777117751"},{"product_id":"mean-well-ntu-1700-212au-true-sine-wave-dc-ac-inverter-1700w-220v-out-12v-in-with-au-socket-with-ac-by-pass-function","title":"Mean Well NTU-1700-212AU True Sine Wave DC-AC Inverter 1700W 220V out 12V in with AU Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 3400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 12Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250282860829,"sku":"NTU-1700-212AU","price":441.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-1700-212au-true-sine-wave-dc-ac-inverter-1700w-220v-out-12v-in-with-au-socket-with-ac-by-pass-function-6264869.jpg?v=1777117751"},{"product_id":"mean-well-ntu-1700-224au-true-sine-wave-dc-ac-inverter-1700w-220v-out-24v-in-with-au-socket-with-ac-by-pass-function","title":"Mean Well NTU-1700-224AU True Sine Wave DC-AC Inverter 1700W 220V out 24V in with AU Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 3400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 12Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250282991901,"sku":"NTU-1700-224AU","price":441.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-1700-224au-true-sine-wave-dc-ac-inverter-1700w-220v-out-24v-in-with-au-socket-with-ac-by-pass-function-8463087.jpg?v=1777117751"},{"product_id":"mean-well-ntu-1700-248au-true-sine-wave-dc-ac-inverter-1700w-220v-out-48v-in-with-au-socket-with-ac-by-pass-function","title":"Mean Well NTU-1700-248AU True Sine Wave DC-AC Inverter 1700W 220V out 48V in with AU Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 3400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400x184x70mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2pcs \/ 12Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250283122973,"sku":"NTU-1700-248AU","price":441.62,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-1700-248au-true-sine-wave-dc-ac-inverter-1700w-220v-out-48v-in-with-au-socket-with-ac-by-pass-function-5525043.jpg?v=1777117751"},{"product_id":"mean-well-ntu-2200-112us-true-sine-wave-dc-ac-inverter-2200w-110v-out-12v-in-with-us-socket-with-ac-by-pass-function","title":"Mean Well NTU-2200-112US True Sine Wave DC-AC Inverter 2200W 110V out 12V in with US Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 4400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250283286813,"sku":"NTU-2200-112US","price":783.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-2200-112us-true-sine-wave-dc-ac-inverter-2200w-110v-out-12v-in-with-us-socket-with-ac-by-pass-function-6594975.jpg?v=1777117751"},{"product_id":"mean-well-ntu-2200-124us-true-sine-wave-dc-ac-inverter-2200w-110v-out-24v-in-with-us-socket-with-ac-by-pass-function","title":"Mean Well NTU-2200-124US True Sine Wave DC-AC Inverter 2200W 110V out 24V in with US Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 4400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250283352349,"sku":"NTU-2200-124US","price":783.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/969eb39e73038edd4b8729b040a918e75c763830_NTU_2200_124US.jpg?v=1775769505"},{"product_id":"mean-well-ntu-2200-148us-true-sine-wave-dc-ac-inverter-2200w-110v-out-48v-in-with-us-socket-with-ac-by-pass-function","title":"Mean Well NTU-2200-148US True Sine Wave DC-AC Inverter 2200W 110V out 48V in with US Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 4400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50250283417885,"sku":"NTU-2200-148US","price":783.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/1d427f2bc1dfdad34faa23da5b97a4f1c51b9705_NTU_2200_148US.jpg?v=1775769513"},{"product_id":"mean-well-ntu-3200-112us-true-sine-wave-dc-ac-inverter-3200w-110v-out-12v-in-with-us-socket-with-ac-by-pass-function","title":"Mean Well NTU-3200-112US True Sine Wave DC-AC Inverter 3200W 110V out 12V in with US Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50273129038109,"sku":"NTU-3200-112US","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/f94826ef1cbb60c85dfed588abd59f7a7a61ddbb_NTU_3200_112US_main.jpg?v=1775769540"},{"product_id":"mean-well-ntu-3200-124us-true-sine-wave-dc-ac-inverter-3200w-110v-out-24v-in-with-us-socket-with-ac-by-pass-function","title":"Mean Well NTU-3200-124US True Sine Wave DC-AC Inverter 3200W 110V out 24V in with US Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50273129070877,"sku":"NTU-3200-124US","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/bdee6327ec24a72b3882aa95fc3eae6129d691b5_NTU_3200_124US_main.jpg?v=1775769565"},{"product_id":"mean-well-ntu-3200-148us-true-sine-wave-dc-ac-inverter-3200w-110v-out-48v-in-with-us-socket-with-ac-by-pass-function","title":"Mean Well NTU-3200-148US True Sine Wave DC-AC Inverter 3200W 110V out 48V in with US Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50273129267485,"sku":"NTU-3200-148US","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-148us-true-sine-wave-dc-ac-inverter-3200w-110v-out-48v-in-with-us-socket-with-ac-by-pass-function-1595754.jpg?v=1777117750"},{"product_id":"mean-well-ntu-3200-212au-true-sine-wave-dc-ac-inverter-3200w-220v-out-12v-in-with-au-socket-with-ac-by-pass-function","title":"Mean Well NTU-3200-212AU True Sine Wave DC-AC Inverter 3200W 220V out 12V in with AU Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50273129300253,"sku":"NTU-3200-212AU","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-212au-true-sine-wave-dc-ac-inverter-3200w-220v-out-12v-in-with-au-socket-with-ac-by-pass-function-1747106.jpg?v=1777117750"},{"product_id":"mean-well-ntu-3200-224au-true-sine-wave-dc-ac-inverter-3200w-220v-out-24v-in-with-au-socket-with-ac-by-pass-function","title":"Mean Well NTU-3200-224AU True Sine Wave DC-AC Inverter 3200W 220V out 24V in with AU Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50273129365789,"sku":"NTU-3200-224AU","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-224au-true-sine-wave-dc-ac-inverter-3200w-220v-out-24v-in-with-au-socket-with-ac-by-pass-function-5212421.jpg?v=1777117750"},{"product_id":"mean-well-ntu-3200-248au-true-sine-wave-dc-ac-inverter-3200w-220v-out-48v-in-with-au-socket-with-ac-by-pass-function","title":"Mean Well NTU-3200-248AU True Sine Wave DC-AC Inverter 3200W 220V out 48V in with AU Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50273129398557,"sku":"NTU-3200-248AU","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-248au-true-sine-wave-dc-ac-inverter-3200w-220v-out-48v-in-with-au-socket-with-ac-by-pass-function-4967383.jpg?v=1777117750"},{"product_id":"mean-well-ntu-3200-112tb-true-sine-wave-dc-ac-inverter-3200w-110v-out-12v-in-with-tb-socket-with-ac-by-pass-function","title":"Mean Well NTU-3200-112TB True Sine Wave DC-AC Inverter 3200W 110V out 12V in with TB Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50308642996509,"sku":"NTU-3200-112TB","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-112tb-true-sine-wave-dc-ac-inverter-3200w-110v-out-12v-in-with-tb-socket-with-ac-by-pass-function-2789908.jpg?v=1777117630"},{"product_id":"mean-well-ntu-3200-112un-true-sine-wave-dc-ac-inverter-3200w-110v-out-12v-in-with-un-socket-with-ac-by-pass-function","title":"Mean Well NTU-3200-112UN True Sine Wave DC-AC Inverter 3200W 110V out 12V in with UN Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50308644110621,"sku":"NTU-3200-112UN","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-112un-true-sine-wave-dc-ac-inverter-3200w-110v-out-12v-in-with-un-socket-with-ac-by-pass-function-7551240.jpg?v=1777117629"},{"product_id":"mean-well-ntu-3200-124tb-true-sine-wave-dc-ac-inverter-3200w-110v-out-24v-in-with-tb-socket-with-ac-by-pass-function","title":"Mean Well NTU-3200-124TB True Sine Wave DC-AC Inverter 3200W 110V out 24V in with TB Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50308644798749,"sku":"NTU-3200-124TB","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-124tb-true-sine-wave-dc-ac-inverter-3200w-110v-out-24v-in-with-tb-socket-with-ac-by-pass-function-2309607.jpg?v=1777117629"},{"product_id":"mean-well-ntu-3200-124un-true-sine-wave-dc-ac-inverter-3200w-110v-out-24v-in-with-unsocket-with-ac-by-pass-function","title":"Mean Well NTU-3200-124UN True Sine Wave DC-AC Inverter 3200W 110V out 24V in with UNSocket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50308644929821,"sku":"NTU-3200-124UN","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-124un-true-sine-wave-dc-ac-inverter-3200w-110v-out-24v-in-with-unsocket-with-ac-by-pass-function-4192193.jpg?v=1777117629"},{"product_id":"mean-well-ntu-3200-148tb-true-sine-wave-dc-ac-inverter-3200w-110v-out-48v-in-with-tb-socket-with-ac-by-pass-function","title":"Mean Well NTU-3200-148TB True Sine Wave DC-AC Inverter 3200W 110V out 48V in with TB Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50308647616797,"sku":"NTU-3200-148TB","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-148tb-true-sine-wave-dc-ac-inverter-3200w-110v-out-48v-in-with-tb-socket-with-ac-by-pass-function-7750316.jpg?v=1777117629"},{"product_id":"mean-well-ntu-3200-148un-true-sine-wave-dc-ac-inverter-3200w-110v-out-48v-in-with-un-socket-with-ac-by-pass-function","title":"Mean Well NTU-3200-148UN True Sine Wave DC-AC Inverter 3200W 110V out 48V in with UN Socket, with AC by-pass function","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50308647649565,"sku":"NTU-3200-148UN","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-148un-true-sine-wave-dc-ac-inverter-3200w-110v-out-48v-in-with-un-socket-with-ac-by-pass-function-9484744.jpg?v=1777117629"},{"product_id":"mean-well-ntu-3200-212cn-true-sine-wave-dc-ac-inverter-3200w-220v-out-12v-in-with-cn-socket","title":"Mean Well NTU-3200-212CN True Sine Wave DC-AC Inverter 3200W 220V out 12V in with CN Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50364177645853,"sku":"NTU-3200-212CN","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-212cn-true-sine-wave-dc-ac-inverter-3200w-220v-out-12v-in-with-cn-socket-7610798.jpg?v=1777117629"},{"product_id":"mean-well-ntu-3200-212eu-true-sine-wave-dc-ac-inverter-3200w-220v-out-12v-in-with-eu-socket","title":"Mean Well NTU-3200-212EU True Sine Wave DC-AC Inverter 3200W 220V out 12V in with EU Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50364177940765,"sku":"NTU-3200-212EU","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-212eu-true-sine-wave-dc-ac-inverter-3200w-220v-out-12v-in-with-eu-socket-8442413.jpg?v=1777117629"},{"product_id":"mean-well-ntu-3200-212tb-true-sine-wave-dc-ac-inverter-3200w-220v-out-12v-in-with-terminal-block","title":"Mean Well NTU-3200-212TB True Sine Wave DC-AC Inverter 3200W 220V out 12V in with Terminal Block","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50364178235677,"sku":"NTU-3200-212TB","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-212tb-true-sine-wave-dc-ac-inverter-3200w-220v-out-12v-in-with-terminal-block-6190304.jpg?v=1777117629"},{"product_id":"mean-well-ntu-3200-212uk-true-sine-wave-dc-ac-inverter-3200w-220v-out-12v-in-with-uk-socket","title":"Mean Well NTU-3200-212UK True Sine Wave DC-AC Inverter 3200W 220V out 12V in with UK Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50364178530589,"sku":"NTU-3200-212UK","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/765ad1f022d1cb6cd318fc3e4368779dc9a8970b_NTU_3200_212UK.jpg?v=1772350295"},{"product_id":"mean-well-ntu-3200-212un-true-sine-wave-dc-ac-inverter-3200w-220v-out-12v-in-with-un-socket","title":"Mean Well NTU-3200-212UN True Sine Wave DC-AC Inverter 3200W 220V out 12V in with UN Socket","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in UPS function(AC by-pass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrue sine wave output (THD\u0026lt;3%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh surge power up to 6400W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature-controlled cooling fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eAC output voltage and frequency selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-25℃~+70℃ wide operating temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003ePower ON-OFF remote control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront panel indicators for operation status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBattery over-discharge protection(low voltage disconnect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSuitable for lead-acid or li-ion batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote controller (IRC1, IRC2, IRC3 accessory sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport RS-232 communication(Communication cable order No.: DS-RJ11-RS232, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry handle accessory available(Order NO.: DS-Carry handle, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\/110\/115\/120VAC;200\/220\/230\/240VAC selectable by DIP S.W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC output waveform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTrue sine wave, THD\u0026lt;3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105~115% load for 180s, 115~150% load for 10s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC I\/P - AC I\/P:3.0KVAC, DC I\/P - AC O\/P:3.0KVAC, AC O\/P - FG:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25~+70°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCB IEC62368-1,Dekra Seal BS EN\/EN62368-1,UL458, E13,EAC TP TC 004,AS\/NZS 62368.1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55032 class A, BS EN\/EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e420x270x98mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1pc \/ 10.4Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"Mean Well","offers":[{"title":"Default Title","offer_id":50364178989341,"sku":"NTU-3200-212UN","price":873.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0678\/9791\/7725\/files\/mean-well-ntu-3200-212un-true-sine-wave-dc-ac-inverter-3200w-220v-out-12v-in-with-un-socket-6478733.jpg?v=1777117629"}],"url":"https:\/\/powersupplymall.com\/collections\/nts-series.oembed?page=2","provider":"powersupplymall.com","version":"1.0","type":"link"}