888.228.9138

Free Shipping over $200 worldwide

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well LOP-300-36 300W 4"×2" Low Profile Open Frame Power Supply 36V

conventional 180W, 300W if using fan, high frequency up to 94%
SKU:
LOP-300-36

$71.41 USD
Shipping calculated at checkout.
|

Your order will be processed within 24 hours

Description

Features:

  • MEAN WELL Patent Number: ZL 202223277512.1
  • 4"x2" compact size with low profile (25.4mm)
  • 80~264Vac input with PFC, No load power consumption <0.5W
  • Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-216
  • 150% peak load @ 3s
  • 180W convection, 300W with FAN 10.98CFM forced-cooled
  • suitable for Class I or Class II installations
  • Overvoltage category III (OVC III)
  • -40 ~+80°C wide range operation temperature
  • High efficiency up to 94%
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Extremely low leakage current, 2 x MOPP, suitable for BF medical applications
  • Operating altitude up to 5000 meters
  • Built-in 12V/0.5A for external FAN
  • 3 years warranty

General Specification

VOLTAGE RANGE

80 ~ 264VAC 113 ~ 370VDC

SETUP, RISE TIME

1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load

INRUSH CURRENT (Typ.)

COLD START 40A/115VAC 80A/230VAC

POWER FACTOR

PF>0.95/230VAC PF>0.98/115VAC at full load

OVERLOAD

105 ~ 150% rated output power,

Protection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed

OVERVOLTAGE

(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover

PROTECTIVE EXTRA-LOW VOLTAGE

IEC/EN61558-2-16 (SELV, 12~48V )

IEC/EN/UL 62368-1 (SELV / ES1,12~48V )

WORKING TEMP.

-40 ~ +80℃ (Refer to "Derating Curve")

SAFETY STANDARDS

CB IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1; TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN60601-1(3.2 Version); UL UL62368-1, ANSI / AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS/NZS 61558-1/-2-16; EAC TPTC 004 approved

WITHSTAND VOLTAGE

I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC

Dimension (LxWxH)

101.6x50.8x25.4mm

Specifications

  • Brand
    Mean Well
  • Series
    Mean Well LOP Series
  • Power Rating
    300 Watt
  • Output Voltage
    36 Volt
  • Rated Current
    5 Ampere
  • No of Output
    1
  • Dimming Control
    None
  • Standards Met
    CB,CCC,CE,EAC,TUV,UL
  • Operation Mode
    Constant Voltage
  • Warranty
    3 Year
  • Length
    4 in
  • Width
    2 in
  • Height
    1 in
  • Weight
    0.46 lb

File Downloads

::specification::

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • iDEAL Wero
  • Mastercard
  • PayPal
  • Shop Pay
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Frequently Asked Questions

What is the output rating of the Mean Well LOP-300-36?

The LOP-300-36 is a 300W open frame AC/DC power supply with a 36V DC output. Its rated output current is 5A. This model is built for applications that need a compact, low-profile 36V power source.

What makes the LOP-300-36 suitable for space-constrained equipment?

This model uses a 4 x 2 inch footprint and a low 25.4 mm profile. Its compact dimensions of 101.6 x 50.8 x 25.4 mm help it fit into equipment where internal space is limited. That makes it a practical option for OEM and embedded power designs.

Can the Mean Well LOP-300-36 be used in medical or regulated equipment designs?

The LOP-300-36 includes certifications covering IEC/EN/UL 62368-1 and IEC/EN/ANSI/AAMI 60601-1, along with additional household and industrial standards listed in the specifications. It also features extremely low leakage current and 2 x MOPP, which supports BF medical application requirements. Buyers should still confirm full end-system compliance for their finished equipment.

What input range does the LOP-300-36 support?

This power supply accepts a wide universal input range of 80 to 264VAC, and it also supports 113 to 370VDC. It includes active power factor correction, with power factor values above 0.95 at 230VAC and above 0.98 at 115VAC at full load. That flexibility helps support global equipment platforms.

How does the LOP-300-36 perform across temperature extremes?

The LOP-300-36 is rated for operation from -40°C to +80°C, based on the derating guidance in the product documentation. It also includes over-temperature protection to help protect the supply under thermal stress. This wide operating range makes it suitable for demanding industrial environments.

Is the LOP-300-36 designed for convection cooling only?

The unit is rated for 180W with convection cooling and up to 300W with 10.98 CFM forced-air cooling. It also includes a built-in 12V/0.5A output for an external fan. For applications that need the full 300W output, buyers should account for the forced-cooling requirement.

What protection features are included in the Mean Well LOP-300-36?

This model includes short circuit, overload, overvoltage, and over-temperature protection. The overload protection operates at 105 to 150 percent of rated output power, with hiccup protection after 3 seconds and automatic recovery after the fault is removed. Overvoltage and over-temperature protection shut down the output and recover according to the conditions described in the specification.

Mean Well LOP-300-36 300W 4"×2" Low Profile Open Frame Power Supply 36V
Mean Well

Mean Well LOP-300-36 300W 4"×2" Low Profile Open Frame Power Supply 36V

$71.41 USD

Features:

General Specification

VOLTAGE RANGE

80 ~ 264VAC 113 ~ 370VDC

SETUP, RISE TIME

1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load

INRUSH CURRENT (Typ.)

COLD START 40A/115VAC 80A/230VAC

POWER FACTOR

PF>0.95/230VAC PF>0.98/115VAC at full load

OVERLOAD

105 ~ 150% rated output power,

Protection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed

OVERVOLTAGE

(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

Protection type : Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover

PROTECTIVE EXTRA-LOW VOLTAGE

IEC/EN61558-2-16 (SELV, 12~48V )

IEC/EN/UL 62368-1 (SELV / ES1,12~48V )

WORKING TEMP.

-40 ~ +80℃ (Refer to "Derating Curve")

SAFETY STANDARDS

CB IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1; TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN60601-1(3.2 Version); UL UL62368-1, ANSI / AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS/NZS 61558-1/-2-16; EAC TPTC 004 approved

WITHSTAND VOLTAGE

I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC

Dimension (LxWxH)

101.6x50.8x25.4mm