Fall Savings: 30% off select MEAN WELL models · Auto-applied in cart.  Shop Now

Free US Shipping over $200Ships from CA · TX · MAWholesale & Trade AccountContact

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well RID-125-1224 AC-DC Dual output enclosed power supply 125W 3.7A

miniature sizeeconomicalwithstand 5G vibration and 70°C operationisolated dual output
SKU RID-125-1224
$40.91 USD
Shipping calculated at checkout.
|

Your order will be processed within 24 hours


Overview

RID-125-1224 is the CH1: 12V / CH2: 24V output model of this series: rated current CH1: 3.7A / CH2: 3.7A, rated power 133.2W, typical efficiency 85%.

Features

  • Isolated output & GND for CH1,CH2
  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage
  • All using 105℃ long life electrolytic capacitors
  • Withstand 5G vibration test
  • LED indicator for power on
  • 100% full load burn-in test
  • High realibility
  • 3 years warranty

Specifications

RID-125-1224Specifications from the official datasheet (2025-12-19 edition)

OUTPUT

OUTPUT NUMBER
CH1 / CH2
DC VOLTAGE
CH1: 12V / CH2: 24V
RATED CURRENT
CH1: 3.7A / CH2: 3.7A
CURRENT RANGENote.3
CH1: 0 ~ 7A / CH2: 0 ~ 5A
RATED POWERNote.6
133.2W
RIPPLE & NOISE (max.)Note.2
CH1: 120mVp-p / CH2: 200mVp-p
VOLTAGE ADJ. RANGE
CH1: 11.4 ~ 13.2V
VOLTAGE TOLERANCENote.3
CH1: ±2.0% / CH2: ±8.0%
LINE REGULATIONNote.4
CH1: ±0.5% / CH2: ±1.0%
LOAD REGULATIONNote.5
CH1: ±1.0% / CH2: ±5.0%
SETUP, RISE TIME
500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
36ms/230VAC 30ms/115VAC at full load

INPUT

VOLTAGE RANGE
88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(300VAC peak 5sec. No damage)
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
85%
AC CURRENT (Typ.)
3A/115VAC 2A/230VAC
INRUSH CURRENT (Typ.)
COLD START 50A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC

PROTECTION

OVERLOAD
110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
CH1: 13.8 ~ 16.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

WORKING TEMP.
-20 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)on CH1 output
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC (Note 7)

SAFETY STANDARDS
UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2(Note 9),-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020

OTHERS

MTBF
2755.4K hrs min. Telcordia SR-332 (Bellcore) ; 425.8K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
199*98*38mm (L*W*H)
PACKING
0.59Kg; 20pcs/12.85Kg/0.85CUFT
Test conditions and notes10
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.(In order to meet tolerance, it is recommended that CH1 load > 5% rated current.)
  4. 4. Line regulation is measured from low line to high line at rated load.
  5. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
  6. 6. Each output can work within current range. But total output power can't exceed rated output power.
  7. 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  8. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  9. 9. Testing harmonic current at 85%load.
  10. 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

RID-125-1224 Mechanical Specification
Mechanical Specification
RID-125-1224 Block Diagram
Block Diagram
RID-125-1224 Derating Curve
Derating Curve

Downloads

FAQ

Can I use the RID-125-1224 for 12V automation hardware in a control panel?

It can fit 12V automation hardware when the load remains within its 3.7A output current and 133.2W power rating. The enclosed construction and isolated dual output support panel-based power distribution for low-voltage control equipment.

Is the RID-125-1224 appropriate for 12V embedded controllers or industrial communication devices?

This model is aligned with 12V embedded or communication hardware because it provides a 12V output with 3.7A available current. It is better matched to devices that need a stable 12V supply than to equipment requiring 5V or 24V rails.

Can the RID-125-1224 support 12V monitoring, sensing, or interface equipment?

Yes, it can serve 12V monitoring or interface equipment in industrial and automation settings if the connected load is sized within 3.7A. The 133.2W platform gives more headroom than the smaller 50W, 65W, or 85W family members.

Is the RID-125-1224 suitable for outdoor cabinets or only indoor equipment spaces?

Its specified operating temperature range is -20°C to +70°C, which supports use in a wide range of equipment environments. The provided specs do not list an IP rating, so weather-exposed outdoor suitability cannot be confirmed from this data alone.

What are the main differences between the RID-125-1224 and the other RID models listed?

The sibling list includes RID-125-1205 at 125.4W, 12V/5V; RID-125-1248 at 138W, 12V/48V; RID-125-2405 at 125.4W, 24V/5V; RID-125-2448 at 144W, 24V/48V; RID-50A at 50W, 5V, 2A; RID-50B at 50W, 5V, 1.4A; RID-65A at 65W, 5V, 3A; RID-65B at 65W, 5V, 2A; RID-85A at 85W, 5V, 4A; and RID-85B at 85W, 5V, 2A. The RID-125-1224 stands out as a 133.2W, 12V/24V model with 3.7A output current per channel.

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Bancontact
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • iDEAL Wero
  • Mastercard
  • PayPal
  • Satispay
  • Shop Pay
  • USDC
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Mean Well RID-125-1224 AC-DC Dual output enclosed power supply 125W 3.7A
Mean Well

Mean Well RID-125-1224 AC-DC Dual output enclosed power supply 125W 3.7A

$40.91 USD

RID-125-1224 is the CH1: 12V / CH2: 24V output model of this series: rated current CH1: 3.7A / CH2: 3.7A, rated power 133.2W, typical efficiency 85%.

Features

  • Isolated output & GND for CH1,CH2
  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage
  • All using 105℃ long life electrolytic capacitors
  • Withstand 5G vibration test
  • LED indicator for power on
  • 100% full load burn-in test
  • High realibility
  • 3 years warranty
View product