Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well LAD-360CU Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 41.5V, UART Signal 7.14A

built-in battery charger and UPS functionTTL signals for status detectionforced UPS mode for battery maintenance1U low profile
SKU LAD-360CU
$62.12 USD
Shipping calculated at checkout.
Model

Select model — 6 in this family

LAD-360CU
|

Your order will be processed within 24 hours


Overview

LAD-360CU is the CH1: 41.5V / CH2: 41.5V output model of this series: rated current CH1: 7.14A / CH2: 1.5A(Battery Charger), rated power 358.56W, typical efficiency 86.5%.

LAD-360 series is a 360W economical AC/DC low profile security power supply with UPS function. Adopting the input range from 90Vac to 264Vac (115Vac/230Vac selectable by switch) and supports output 27.6V, 41.5V and 55.2Vdc. With high efficiency up to 86.5% and built-in AC, battery switch for easy maintenance. In addition, LAD-360 series not only provide TTL signals for AC OK, battery disconnect, battery reverse polarity (No damage), battery low detection, battery full and discharge, but also possess UART version so the users can monitor and control the status of the units, that enhance easy way for integration into security and fire systems directly.

Features

  • Built-in battery charger and UPS function
  • TTL signals for status detection: AC OK, Battery disconnect, Battery reverse polarity, Battery low, Battery full and Discharge (Blank version only)
  • UART Communication (U version only)
  • Built-in buzzer alarm (U version only)
  • Built-in AC and battery circuit ON/OFF switches enhance safetyness during maintenance
  • Forced UPS mode for battery maintenance
  • Protections: Short circuit / Overload / Over voltage / Over temperature / Battery low voltage / Battery reverse polarity (No damage)
  • -20 ~ +60℃ wide operating temperature
  • Output voltage adjustable (-20%~+5%) for CH1 by VR
  • Suitable for lead acid and lithium-ion batteries
  • Design refer to GB17945/GB4717(U version only) system requirement
  • 1U low profile (30 mm)
  • 3 years warranty

Specifications

LAD-360CUSpecifications from the official datasheet (2026-01-23 edition)

OUTPUT

OUTPUT NUMBER
CH1 / CH2
DC VOLTAGE
CH1: 41.5V / CH2: 41.5V
RATED CURRENT
CH1: 7.14A / CH2: 1.5A(Battery Charger)
CURRENT RANGE
CH1: 0 ~ 8.64A / CH2: --------
RATED POWER
358.56W
RIPPLE & NOISE (max.)Note.2
CH1: 240mVp-p / CH2: --------
VOLTAGE ADJ. RANGE
CH1: 32.4 ~ 43.5V
VOLTAGE TOLERANCENote.3
CH1: ±1.0% / CH2: --------
LINE REGULATION
CH1: ±0.5% / CH2: --------
LOAD REGULATION
CH1: ±0.5% / CH2: --------
SETUP, RISE TIME
2000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 12ms/115VAC at full load
BATTERY STATIC DISCHARGE CURRENT
<100μA

INPUT

VOLTAGE RANGE
90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (Default switch at 230VAC)
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
86.5%
AC CURRENT (Typ.)
8A/115VAC 4A/230VAC
INRUSH CURRENT (Typ.)
COLD START 60A/115VAC 60A/230VAC
LEAKAGE CURRENT
<0.5mA / 240VAC

PROTECTION

OVERLOAD
CH1:105 ~ 135% CH2:90 ~ 110% Protection type : CH1 OLP, CH2 with battery: The unit will enter to UPS mode when CH1 is around 105%~120%, when total output of CH1 + CH2 reach around 125%~135% output shuts down CH1 OLP, CH2 without battery:Shut down o/p voltage,re-power on to removed CH2 : Constant current limiting; fault condition does not affect CH1 working,recovers automatically after fault condition is removed (External fuse is mandatory in series connection with battery for protection)
OVER VOLTAGE
CH1:47 ~ 55V Protection type : Shut down o/p voltage, re-power on to removed
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to removed
BATTERY REVERSE POLARITY
Protected when reverse polarity , no damage, recovers automatically after fault condition is removed
BATTERY CUTOFF
32V±0.5V

FUNCTION

AC OK
115VAC Input : Signals AC failure and activates when input voltage <75VAC Recover the main power supply when input voltage >85VAC 230VAC Input : Signals AC failure and activates when input voltage <165VAC Recover the main power supply when input voltage >175VAC
CHARGER CIRCUIT FAIL
Battery disconnected, battery reverse polarity , signal failure
BUZZER ALARM
Battery low( fire alarm system selectable by UART) AC fail, Battery low, battery disconnected, battery reverse connect, overload status (evacuation system selectable by UART)

ENVIRONMENT

WORKING TEMP.
-20 ~ +60℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-30 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
UL62368-1, BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved; Design refer to GB 17945-2010, GB4717
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55032 (CISPR32), EAC TP TC 020Class A
RadiatedBS EN/EN55032 (CISPR32), EAC TP TC 020Class A
EMC IMMUNITY
ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, 8KV air; Level 2, 6KV contact; criteria A
RadiatedBS EN/EN61000-4-3Level 3, 10V/m; criteria A
EFT / BurstBS EN/EN61000-4-4Level 3, 2KV; criteria A
SurgeBS EN/EN61000-4-5Level 3, 1KV/Line-Line ;2KV/Line-FG ;criteria A
ConductedBS EN/EN61000-4-6Level 3, 10V; criteria A
Magnetic FieldBS EN/EN61000-4-8Level 4, 30A/m; criteria A

OTHERS

MTBF
1160.5K hrs min. Telcordia SR-332 (Bellcore); 126.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
215*115*30mm (L*W*H)
PACKING
0.75Kg; 15pcs/12.25Kg/0.7CUFT
Test conditions and notes6
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. Radiation testing requires adding 13*26*30NIZN magnetic loops or buckles to the battery output wire. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. 5. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions: a) the end-devices is used within the European Union, and b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c) the power supply is: - installed in end-devices with average or continuous input power greater than 75W, or - belong to part of a lighting system Exception: Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2 a) professional equipment with a total rated input power greater than 1000W; b) symmetrically controlled heating elements with a rated power less than or equal to 200W
  6. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

LAD-360CU Block Diagram
Block Diagram
LAD-360CU Suggested Application
Suggested Application
LAD-360CU ※ Remote UPS mode
※ Remote UPS mode
LAD-360CU 2.2 Charging Curve for Different Battery(U version only)
2.2 Charging Curve for Different Battery(U version only)
LAD-360CU ◎ Charging curve
◎ Charging curve
LAD-360CU 2.3 Mode Selection for Buzzer(U version only)
2.3 Mode Selection for Buzzer(U version only)
LAD-360CU 2.4 Battery Inspection
2.4 Battery Inspection
LAD-360CU ※ LAD-360CU
※ LAD-360CU
LAD-360CU ※ LAD-360DU
※ LAD-360DU
LAD-360CU 2.5 UART Communication Interface(U version only)
2.5 UART Communication Interface(U version only)
LAD-360CU L A D - 3 6 0 series
L A D - 3 6 0 series
LAD-360CU L A D - 3 6 0 series (2)
L A D - 3 6 0 series (2)
LAD-360CU L A D - 3 6 0 series (3)
L A D - 3 6 0 series (3)
LAD-360CU L A D - 3 6 0 series (4)
L A D - 3 6 0 series (4)
LAD-360CU Illustration (page 9)
Illustration (page 9)
LAD-360CU Illustration (page 9)
Illustration (page 9)

Typical applications

  • Fire emergency and evacuation system
  • Public safety battery back-up
  • Security system
  • Uninterruptible DC-UPS system
  • Central monitoring system
  • Industrial automation

Downloads

FAQ

What is the Mean Well LAD-360CU designed for?

The LAD-360CU is a 360W security and fire alarm power supply with a built-in battery charger and UPS function. It is intended for systems that need regulated 41.5V DC output plus battery-backed continuity and status monitoring.

What output does the LAD-360CU provide?

This model provides a 41.5V DC output and is rated for 360W total power. Its rated current is 7.14A, making it suitable for higher-power security and fire system applications that require this voltage class.

Does the LAD-360CU support battery backup operation?

Yes. The LAD-360CU includes a built-in battery charger and UPS function, and it also supports a forced start UPS mode for emergency, maintenance or testing. Its charging curve can be set for lead-acid or lithium-ion batteries.

What monitoring or status signals are available on this power supply?

The LAD-360CU reports status through its UART communication interface. Available status detection includes AC OK, battery disconnect, battery reverse polarity, battery low, battery full, and discharge, plus a built-in buzzer alarm.

What protections are built into the Mean Well LAD-360CU?

This model includes protection for overload, over voltage, over temperature, battery reverse polarity, and a battery cutoff at 32V±0.5V. The battery reverse polarity protection is specified as no-damage protection.

Is the LAD-360CU suitable for demanding operating environments?

It is rated for operation from -20°C to +60°C (refer to the derating curve), which supports use in a wide range of commercial and industrial indoor environments. The unit also has a low-profile 30mm-high form factor for space-sensitive equipment designs.

What certifications or standards does the LAD-360CU meet?

The LAD-360CU is approved to UL62368-1, BS EN/EN62368-1, AS/NZS62368.1, and EAC TP TC 004 standards. Its design also refers to GB 17945-2010, which is relevant for fire system applications.

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Bancontact
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • iDEAL Wero
  • Mastercard
  • PayPal
  • Satispay
  • Shop Pay
  • USDC
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Other LAD Series Models

19 other models
ModelPower Voltage Current IP RatingPrice
Mean Well LAD-600B Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 27.6V, TTL Signal 18.74A 600.02W 27.6V 18.74A IP20$85.20 View
Mean Well LAD-600DU Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 55.2V, UART Signal 7.87A 600.02W 55.2V 7.87A IP20$91.35 View
Mean Well LAD-600D Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 55.2V, TTL Signal 7.87A 600.02W 55.2V 7.87A IP20$85.20 View
Mean Well LAD-600CU Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 41.5V, UART Signal 11.45A 599.67W 41.5V 11.45A IP20$91.35 View
Mean Well LAD-600C Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 41.5V, TTL Signal 11.45A 599.67W 41.5V 11.45A IP20$85.20 View
Mean Well LAD-600BU Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 27.6V, UART Signal 18.74A 600.02W 27.6V 18.74A IP20$91.35 View
Mean Well LAD-360DU Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 55.2V, UART Signal 5.03A 360.46W 55.2V 5.03A IP20$62.12 View
Mean Well LAD-360D Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 55.2V, TTL Signal 5.03A 360.46W 55.2V 5.03A IP20$51.83 View
Mean Well LAD-360C Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 41.5V, TTL Signal 7.14A 358.56W 41.5V 7.14A IP20$51.83 View
Mean Well LAD-360BU Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 27.6V, UART Signal 11.5A 358.8W 27.6V 11.5A IP20$62.12 View
Mean Well LAD-360B Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 27.6V, TTL Signal 11.5A 358.8W 27.6V 11.5A IP20$51.83 View
Mean Well LAD-240D Security/Fire Alarm PSU with Battery Charger/UPS, 240W, 55.2V 3.4A 242.88W 55.2V 3.4A IP20$47.98 View
Mean Well LAD-240C Security/Fire Alarm PSU with Battery Charger/UPS, 240W, 41.5V 4.78A 239.87W 41.5V 4.78A IP20$46.98 View
Mean Well LAD-240B Security/Fire Alarm PSU with Battery Charger/UPS, 240W, 27.6V 7.7A 240.12W 27.6V 7.7A IP20$45.98 View
Mean Well LAD-240A Security/Fire Alarm PSU with Battery Charger/UPS, 240W, 13.8V 16.4A 240.12W 13.8V 16.4A IP20$44.98 View
Mean Well LAD-120D Security/Fire Alarm PSU with Battery Charger/UPS, 120W, 55.2V 1.21A 121.99W 55.2V 1.21A IP20$38.73 View
Mean Well LAD-120C Security/Fire Alarm PSU with Battery Charger/UPS, 120W, 41.5V 1.9A 120.35W 41.5V 1.9A IP20$38.73 View
Mean Well LAD-120B Security/Fire Alarm PSU with Battery Charger/UPS, 120W, 27.6V 3.4A 121.4W 27.6V 3.4A IP20$38.73 View
Mean Well LAD-120A Security/Fire Alarm PSU with Battery Charger/UPS, 120W, 13.8V 7.7A 120W 13.8V 7.7A IP20$38.73 View
Mean Well LAD-360CU Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 41.5V, UART Signal 7.14A - LAD-360CU - powersupplymall.com
Mean Well

Mean Well LAD-360CU Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 41.5V, UART Signal 7.14A

$62.12 USD

LAD-360CU is the CH1: 41.5V / CH2: 41.5V output model of this series: rated current CH1: 7.14A / CH2: 1.5A(Battery Charger), rated power 358.56W, typical efficiency 86.5%.

LAD-360 series is a 360W economical AC/DC low profile security power supply with UPS function. Adopting the input range from 90Vac to 264Vac (115Vac/230Vac selectable by switch) and supports output 27.6V, 41.5V and 55.2Vdc. With high efficiency up to 86.5% and built-in AC, battery switch for easy maintenance. In addition, LAD-360 series not only provide TTL signals for AC OK, battery disconnect, battery reverse polarity (No damage), battery low detection, battery full and discharge, but also possess UART version so the users can monitor and control the status of the units, that enhance easy way for integration into security and fire systems directly.

Features

  • Built-in battery charger and UPS function
  • TTL signals for status detection: AC OK, Battery disconnect, Battery reverse polarity, Battery low, Battery full and Discharge (Blank version only)
  • UART Communication (U version only)
  • Built-in buzzer alarm (U version only)
  • Built-in AC and battery circuit ON/OFF switches enhance safetyness during maintenance
  • Forced UPS mode for battery maintenance
  • Protections: Short circuit / Overload / Over voltage / Over temperature / Battery low voltage / Battery reverse polarity (No damage)
  • -20 ~ +60℃ wide operating temperature
  • Output voltage adjustable (-20%~+5%) for CH1 by VR
  • Suitable for lead acid and lithium-ion batteries
  • Design refer to GB17945/GB4717(U version only) system requirement
  • 1U low profile (30 mm)
  • 3 years warranty

Typical applications

  • Fire emergency and evacuation system
  • Public safety battery back-up
  • Security system
  • Uninterruptible DC-UPS system
  • Central monitoring system
  • Industrial automation

Model

  • 120W 41.5V
  • 240W 41.5V
  • 360W 41.5V
  • 360W UART 41.5V
  • 600W 41.5V
  • 600W UART 41.5V
View product