Mean Well LAD-360CU Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 41.5V, UART Signal 7.14A
Notify me when it's back in stock
Your order will be processed within 24 hours
Overview
LAD-360CU is the CH1: 41.5V / CH2: 41.5V output model of this series: rated current CH1: 7.14A / CH2: 1.5A(Battery Charger), rated power 358.56W, typical efficiency 86.5%.
LAD-360 series is a 360W economical AC/DC low profile security power supply with UPS function. Adopting the input range from 90Vac to 264Vac (115Vac/230Vac selectable by switch) and supports output 27.6V, 41.5V and 55.2Vdc. With high efficiency up to 86.5% and built-in AC, battery switch for easy maintenance. In addition, LAD-360 series not only provide TTL signals for AC OK, battery disconnect, battery reverse polarity (No damage), battery low detection, battery full and discharge, but also possess UART version so the users can monitor and control the status of the units, that enhance easy way for integration into security and fire systems directly.
Features
- Built-in battery charger and UPS function
- TTL signals for status detection: AC OK, Battery disconnect, Battery reverse polarity, Battery low, Battery full and Discharge (Blank version only)
- UART Communication (U version only)
- Built-in buzzer alarm (U version only)
- Built-in AC and battery circuit ON/OFF switches enhance safetyness during maintenance
- Forced UPS mode for battery maintenance
- Protections: Short circuit / Overload / Over voltage / Over temperature / Battery low voltage / Battery reverse polarity (No damage)
- -20 ~ +60℃ wide operating temperature
- Output voltage adjustable (-20%~+5%) for CH1 by VR
- Suitable for lead acid and lithium-ion batteries
- Design refer to GB17945/GB4717(U version only) system requirement
- 1U low profile (30 mm)
- 3 years warranty
Specifications
OUTPUT
- OUTPUT NUMBER
- CH1 / CH2
- DC VOLTAGE
- CH1: 41.5V / CH2: 41.5V
- RATED CURRENT
- CH1: 7.14A / CH2: 1.5A(Battery Charger)
- CURRENT RANGE
- CH1: 0 ~ 8.64A / CH2: --------
- RATED POWER
- 358.56W
- RIPPLE & NOISE (max.)Note.2
- CH1: 240mVp-p / CH2: --------
- VOLTAGE ADJ. RANGE
- CH1: 32.4 ~ 43.5V
- VOLTAGE TOLERANCENote.3
- CH1: ±1.0% / CH2: --------
- LINE REGULATION
- CH1: ±0.5% / CH2: --------
- LOAD REGULATION
- CH1: ±0.5% / CH2: --------
- SETUP, RISE TIME
- 2000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 12ms/115VAC at full load
- BATTERY STATIC DISCHARGE CURRENT
- <100μA
INPUT
- VOLTAGE RANGE
- 90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (Default switch at 230VAC)
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 86.5%
- AC CURRENT (Typ.)
- 8A/115VAC 4A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 60A/115VAC 60A/230VAC
- LEAKAGE CURRENT
- <0.5mA / 240VAC
PROTECTION
- OVERLOAD
- CH1:105 ~ 135% CH2:90 ~ 110% Protection type : CH1 OLP, CH2 with battery: The unit will enter to UPS mode when CH1 is around 105%~120%, when total output of CH1 + CH2 reach around 125%~135% output shuts down CH1 OLP, CH2 without battery:Shut down o/p voltage,re-power on to removed CH2 : Constant current limiting; fault condition does not affect CH1 working,recovers automatically after fault condition is removed (External fuse is mandatory in series connection with battery for protection)
- OVER VOLTAGE
- CH1:47 ~ 55V Protection type : Shut down o/p voltage, re-power on to removed
- OVER TEMPERATURE
- Protection type : Shut down o/p voltage, re-power on to removed
- BATTERY REVERSE POLARITY
- Protected when reverse polarity , no damage, recovers automatically after fault condition is removed
- BATTERY CUTOFF
- 32V±0.5V
FUNCTION
- AC OK
- 115VAC Input : Signals AC failure and activates when input voltage <75VAC Recover the main power supply when input voltage >85VAC 230VAC Input : Signals AC failure and activates when input voltage <165VAC Recover the main power supply when input voltage >175VAC
- CHARGER CIRCUIT FAIL
- Battery disconnected, battery reverse polarity , signal failure
- BUZZER ALARM
- Battery low( fire alarm system selectable by UART) AC fail, Battery low, battery disconnected, battery reverse connect, overload status (evacuation system selectable by UART)
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +60℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -30 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved; Design refer to GB 17945-2010, GB4717
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32), EAC TP TC 020 Class A Radiated BS EN/EN55032 (CISPR32), EAC TP TC 020 Class A - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 6KV contact; criteria A Radiated BS EN/EN61000-4-3 Level 3, 10V/m; criteria A EFT / Burst BS EN/EN61000-4-4 Level 3, 2KV; criteria A Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line ;2KV/Line-FG ;criteria A Conducted BS EN/EN61000-4-6 Level 3, 10V; criteria A Magnetic Field BS EN/EN61000-4-8 Level 4, 30A/m; criteria A
OTHERS
- MTBF
- 1160.5K hrs min. Telcordia SR-332 (Bellcore); 126.5K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 215*115*30mm (L*W*H)
- PACKING
- 0.75Kg; 15pcs/12.25Kg/0.7CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. Radiation testing requires adding 13*26*30NIZN magnetic loops or buckles to the battery output wire. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions: a) the end-devices is used within the European Union, and b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c) the power supply is: - installed in end-devices with average or continuous input power greater than 75W, or - belong to part of a lighting system Exception: Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2 a) professional equipment with a total rated input power greater than 1000W; b) symmetrically controlled heating elements with a rated power less than or equal to 200W
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Fire emergency and evacuation system
- Public safety battery back-up
- Security system
- Uninterruptible DC-UPS system
- Central monitoring system
- Industrial automation
Downloads
Datasheet1
FAQ
What is the Mean Well LAD-360CU designed for?
The LAD-360CU is a 360W security and fire alarm power supply with a built-in battery charger and UPS function. It is intended for systems that need regulated 41.5V DC output plus battery-backed continuity and status monitoring.
What output does the LAD-360CU provide?
This model provides a 41.5V DC output and is rated for 360W total power. Its rated current is 7.14A, making it suitable for higher-power security and fire system applications that require this voltage class.
Does the LAD-360CU support battery backup operation?
Yes. The LAD-360CU includes a built-in battery charger and UPS function, and it also supports a forced start UPS mode for emergency, maintenance or testing. Its charging curve can be set for lead-acid or lithium-ion batteries.
What monitoring or status signals are available on this power supply?
The LAD-360CU reports status through its UART communication interface. Available status detection includes AC OK, battery disconnect, battery reverse polarity, battery low, battery full, and discharge, plus a built-in buzzer alarm.
What protections are built into the Mean Well LAD-360CU?
This model includes protection for overload, over voltage, over temperature, battery reverse polarity, and a battery cutoff at 32V±0.5V. The battery reverse polarity protection is specified as no-damage protection.
Is the LAD-360CU suitable for demanding operating environments?
It is rated for operation from -20°C to +60°C (refer to the derating curve), which supports use in a wide range of commercial and industrial indoor environments. The unit also has a low-profile 30mm-high form factor for space-sensitive equipment designs.
What certifications or standards does the LAD-360CU meet?
The LAD-360CU is approved to UL62368-1, BS EN/EN62368-1, AS/NZS62368.1, and EAC TP TC 004 standards. Its design also refers to GB 17945-2010, which is relevant for fire system applications.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other LAD Series Models
19 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.