Select model — 6 in this family

LAD-600C
|

Your order will be processed within 24 hours


Overview

LAD-600C is the model of this series: rated power 599.67W, typical efficiency 91%. Type Blank: TTL signal only.

LAD-600 series is a 600W economical AC/DC low profile security power supply with UPS function. Adopting the input range from 90Vac to 264Vac (115Vac/230Vac selectable by switch) and supports output 27.6V, 41.5V and 55.2Vdc. With high efficiency up to 91% and built-in AC, battery switch for easy maintenance. In addition, LAD-600 series not only provide TTL signals for AC OK, battery disconnect, battery reverse polarity (No damage), battery low detection, battery full and discharge, but also possess UART version so the users can monitor and control the status of the units, that enhance easy way for integration into security and fire systems directly.

Features

  • Built-in battery charger UPS function
  • TTL signals for status detection: AC OK, Battery disconnect, Battery reverse polarity, Battery low, Battery full and Discharge (Blank version only)
  • UART Communication (U version only)
  • Built-in buzzer alarm (U version only)
  • Built-in AC and battery circuit ON/OFF switches enhance safetyness during maintenance
  • Forced UPS mode for battery maintenance
  • Protections: Short circuit / Overload / Over voltage / Over temperature / Battery low voltage / Battery reverse polarity (No damage)
  • -20 ~ +60℃ wide operating temperature
  • Output voltage adjustable (-20%~+5%) for CH1 by VR
  • Suitable for lead acid and lithium-ion batteries
  • Design refer to GB17945/GB4717(U version only) system requirement
  • 1U low profile
  • 3 years warranty

Model encoding

LAD-600C model encoding: what each part of the model name means
TypeFunction
Blank (this model)TTL signal only
UUART Communication only

Specifications

LAD-600CSpecifications from the official datasheet (2024-10-30 edition)

OUTPUT

OUTPUT NUMBER
CH1, CH2
DC VOLTAGE (CH1)
41.5V
DC VOLTAGE (CH2)
41.5V
RATED CURRENT (CH1)
11.45A
RATED CURRENT (CH2)
3A(Battery Charger)
CURRENT RANGE (CH1)
0 ~ 14.45A
CURRENT RANGE (CH2)
--------
RATED POWER
599.67W
RIPPLE & NOISE (max.) (CH1)Note.2
360mVp-p
RIPPLE & NOISE (max.) (CH2)Note.2
--------
VOLTAGE ADJ. RANGE
CH1: 32.4 ~ 43.5V
VOLTAGE TOLERANCE (CH1)Note.3
±1.0%
VOLTAGE TOLERANCE (CH2)Note.3
--------
LINE REGULATION (CH1)
±0.5%
LINE REGULATION (CH2)
--------
LOAD REGULATION (CH1)
±0.5%
LOAD REGULATION (CH2)
--------
SETUP, RISE TIME
2000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 12ms/115VAC at full load
BATTERY STATIC DISCHARGE CURRENT
<100μA

INPUT

VOLTAGE RANGE
90 ~ 132VAC / 180 ~ 264VAC by switch 240 ~ 370VDC (Default switch at 230VAC)
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
91%
AC CURRENT (Typ.)
12A/115VAC 7.5A/230VAC
INRUSH CURRENT (Typ.)
COLD START 35A/115VAC 60A/230VAC
LEAKAGE CURRENT
<0.5mA Peak / 240VAC

PROTECTION

OVERLOADNote.4
CH1:105 ~ 135% CH2:90 ~ 110% Protection type : CH1 OLP, CH2 with battery: The unit will enter to UPS mode when CH1 is around 105%~120%, when total output of CH1 + CH2 reach around 125%~135% output shuts down CH1 OLP, CH2 without battery:Shut down o/p voltage,re-power on to removed CH2 : Constant current limiting; fault condition does not affect CH1 working,recovers automatically after fault condition is removed (External fuse is mandatory in series connection with battery for protection)
OVER VOLTAGENote.4
CH1:47 ~ 55V Protection type : Shut down o/p voltage, re-power on to removed
OVER TEMPERATURENote.4
Protection type : Shut down o/p voltage, re-power on to removed
BATTERY REVERSE POLARITY
Protected when reverse polarity , no damage, recovers automatically after fault condition is removed
BATTERY CUTOFF
32V±0.5V

FUNCTION

AC OK
TTL signal, High / Open : AC Fail ; Low : AC OK ; Ice : max. 30mA@ 50VDC
BATTERY DISCONNECT/ REVERSE POLARITY
TTL signal, High / Open : Battery connect/normal ; Low : Battery disconnect/reverse polarity; Ice : max. 30mA@ 50VDC
BATTERY LOW
TTL signal, High / Open : Battery normal ; Low : Battery low; Ice : max. 30mA@ 50VDC
BATTERY FULL
TTL signal, High / Open : Battery charging ; Low : Battery full ; Ice : max. 30mA@ 50VDC
DISCHARGE
TTL signal, High / Open : Charge ; Low : Discharge ; Ice : max. 30mA@ 50VDC

ENVIRONMENT

WORKING TEMP.
-20 ~ +60℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-30 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
UL62368-1, BS EN/EN62368-1,AS/NZS62368.1, EAC TP TC 004 approved; Design refer to GB 17945-2010
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55032 (CISPR32), EAC TP TC 020Class A
RadiatedBS EN/EN55032 (CISPR32), EAC TP TC 020Class A
EMC IMMUNITY
ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, 8KV air; Level 2, 6KV contact; criteria A
RadiatedBS EN/EN61000-4-3Level 3, 10V/m; criteria A
EFT / BurstBS EN/EN61000-4-4Level 3, 2KV; criteria A
SurgeBS EN/EN61000-4-5Level 3, 1KV/Line-Line; 2KV/Line-FG ;criteria A
ConductedBS EN/EN61000-4-6Level 3, 10V; criteria A
Magnetic FieldBS EN/EN61000-4-8Level 4, 30A/m; criteria A

OTHERS

MTBF
1154.4K hrs min. Telcordia SR-332 (Bellcore); 169.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
225*124*41mm (L*W*H)
PACKING
1.02Kg; 12pcs/13.5Kg/0.78CUFT
Test conditions and notes7
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Once the protection is triggered, the input voltage needs to be disconnected, and the cold machine will wait for 3 minutes before restarting.
  5. 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. All the radiation tests require an additional 20*30*13 NIZN magnetic clasp or magnetic ring to the battery output line. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  6. 6. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions: a) the end-devices is used within the European Union, and b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c) the power supply is: - installed in end-devices with average or continuous input power greater than 75W, or - belong to part of a lighting system Exception: Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2 a) professional equipment with a total rated input power greater than 1000W; b) symmetrically controlled heating elements with a rated power less than or equal to 200W
  7. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

LAD-600C Block Diagram
Block Diagram
LAD-600C Suggested Application
Suggested Application
LAD-600C L A D - 6 0 0 series (2)
L A D - 6 0 0 series (2)
LAD-600C L A D - 6 0 0 series (3)
L A D - 6 0 0 series (3)
LAD-600C L A D - 6 0 0 series (4)
L A D - 6 0 0 series (4)
LAD-600C Illustration (page 9)
Illustration (page 9)
LAD-600C Illustration (page 9)
Illustration (page 9)

Typical applications

  • Fire emergency and evacuation system
  • Public safety battery back-up
  • Security system
  • Uninterruptible DC-UPS system
  • Central monitoring system
  • Industrial automation

Downloads

FAQ

What is the Mean Well LAD-600C designed for?

The LAD-600C is a 600W security and fire alarm power supply with built-in battery charger and UPS function. It is intended for systems that need a regulated 41.5V DC output and battery-backed continuity during AC power loss.

Does the LAD-600C support battery backup operation?

Yes. This model includes both a built-in battery charger and UPS functionality, so it is designed for applications that require backup power support. It also includes a forced UPS mode for battery maintenance.

What battery types are compatible with the LAD-600C?

Mean Well's sheet lists selectable lead-acid and Li-ion charging curves only for the UART version (LAD-600CU). For the LAD-600C itself, the sheet specifies a 3A battery charger output on CH2 with a battery cutoff at 32V±0.5V for security or fire alarm backup power systems.

What status monitoring signals does the LAD-600C provide?

This model provides TTL status signals for AC OK, battery disconnect, battery reverse polarity, battery low, battery full, and discharge. These signals help support system-level status detection and fault monitoring in more advanced installations.

What are the main electrical ratings of the LAD-600C?

The LAD-600C is rated at 600W with a 41.5V DC output and 11.45A rated current. Its CH1 output voltage is adjustable from 32.4V to 43.5V, which allows output trimming within the specified range.

Is the LAD-600C suitable for demanding operating environments?

It is built for a wide operating temperature range of -20°C to +60°C, which suits many indoor industrial, security, and fire system environments. The unit also includes protection against overload, over voltage, over temperature, battery reverse polarity, and a battery cutoff at 32V±0.5V.

What certifications and form factor does the LAD-600C offer?

The LAD-600C is approved to UL62368-1, EN62368-1, AS/NZS62368.1, and EAC TP TC 004, with design reference to GB 17945-2010. It measures 225 x 124 x 41 mm (L x W x H), which can be useful where space is limited.

Payment & Security

Payment methods

  • Amazon
  • American Express
  • Apple Pay
  • Bancontact
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • iDEAL Wero
  • Mastercard
  • PayPal
  • Satispay
  • Shop Pay
  • USDC
  • Venmo
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Other LAD Series Models

19 other models
ModelPower Voltage Current IP RatingPrice
Mean Well LAD-600B Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 27.6V, TTL Signal 18.74A 600.02W 27.6V 18.74A IP20$85.20 View
Mean Well LAD-600DU Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 55.2V, UART Signal 7.87A 600.02W 55.2V 7.87A IP20$91.35 View
Mean Well LAD-600D Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 55.2V, TTL Signal 7.87A 600.02W 55.2V 7.87A IP20$85.20 View
Mean Well LAD-600CU Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 41.5V, UART Signal 11.45A 599.67W 41.5V 11.45A IP20$91.35 View
Mean Well LAD-600BU Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 27.6V, UART Signal 18.74A 600.02W 27.6V 18.74A IP20$91.35 View
Mean Well LAD-360DU Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 55.2V, UART Signal 5.03A 360.46W 55.2V 5.03A IP20$62.12 View
Mean Well LAD-360D Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 55.2V, TTL Signal 5.03A 360.46W 55.2V 5.03A IP20$51.83 View
Mean Well LAD-360CU Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 41.5V, UART Signal 7.14A 358.56W 41.5V 7.14A IP20$62.12 View
Mean Well LAD-360C Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 41.5V, TTL Signal 7.14A 358.56W 41.5V 7.14A IP20$51.83 View
Mean Well LAD-360BU Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 27.6V, UART Signal 11.5A 358.8W 27.6V 11.5A IP20$62.12 View
Mean Well LAD-360B Security/Fire Alarm PSU with Battery Charger/UPS, 360W, 27.6V, TTL Signal 11.5A 358.8W 27.6V 11.5A IP20$51.83 View
Mean Well LAD-240D Security/Fire Alarm PSU with Battery Charger/UPS, 240W, 55.2V 3.4A 242.88W 55.2V 3.4A IP20$47.98 View
Mean Well LAD-240C Security/Fire Alarm PSU with Battery Charger/UPS, 240W, 41.5V 4.78A 239.87W 41.5V 4.78A IP20$46.98 View
Mean Well LAD-240B Security/Fire Alarm PSU with Battery Charger/UPS, 240W, 27.6V 7.7A 240.12W 27.6V 7.7A IP20$45.98 View
Mean Well LAD-240A Security/Fire Alarm PSU with Battery Charger/UPS, 240W, 13.8V 16.4A 240.12W 13.8V 16.4A IP20$44.98 View
Mean Well LAD-120D Security/Fire Alarm PSU with Battery Charger/UPS, 120W, 55.2V 1.21A 121.99W 55.2V 1.21A IP20$38.73 View
Mean Well LAD-120C Security/Fire Alarm PSU with Battery Charger/UPS, 120W, 41.5V 1.9A 120.35W 41.5V 1.9A IP20$38.73 View
Mean Well LAD-120B Security/Fire Alarm PSU with Battery Charger/UPS, 120W, 27.6V 3.4A 121.4W 27.6V 3.4A IP20$38.73 View
Mean Well LAD-120A Security/Fire Alarm PSU with Battery Charger/UPS, 120W, 13.8V 7.7A 120W 13.8V 7.7A IP20$38.73 View
Mean Well LAD-600C Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 41.5V, TTL Signal 11.45A - LAD-600C - powersupplymall.com
Mean Well

Mean Well LAD-600C Security/Fire Alarm PSU with Battery Charger/UPS, 600W, 41.5V, TTL Signal 11.45A

$85.20 USD

LAD-600C is the model of this series: rated power 599.67W, typical efficiency 91%. Type Blank: TTL signal only.

LAD-600 series is a 600W economical AC/DC low profile security power supply with UPS function. Adopting the input range from 90Vac to 264Vac (115Vac/230Vac selectable by switch) and supports output 27.6V, 41.5V and 55.2Vdc. With high efficiency up to 91% and built-in AC, battery switch for easy maintenance. In addition, LAD-600 series not only provide TTL signals for AC OK, battery disconnect, battery reverse polarity (No damage), battery low detection, battery full and discharge, but also possess UART version so the users can monitor and control the status of the units, that enhance easy way for integration into security and fire systems directly.

Features

  • Built-in battery charger UPS function
  • TTL signals for status detection: AC OK, Battery disconnect, Battery reverse polarity, Battery low, Battery full and Discharge (Blank version only)
  • UART Communication (U version only)
  • Built-in buzzer alarm (U version only)
  • Built-in AC and battery circuit ON/OFF switches enhance safetyness during maintenance
  • Forced UPS mode for battery maintenance
  • Protections: Short circuit / Overload / Over voltage / Over temperature / Battery low voltage / Battery reverse polarity (No damage)
  • -20 ~ +60℃ wide operating temperature
  • Output voltage adjustable (-20%~+5%) for CH1 by VR
  • Suitable for lead acid and lithium-ion batteries
  • Design refer to GB17945/GB4717(U version only) system requirement
  • 1U low profile
  • 3 years warranty

Typical applications

  • Fire emergency and evacuation system
  • Public safety battery back-up
  • Security system
  • Uninterruptible DC-UPS system
  • Central monitoring system
  • Industrial automation

Model

  • 120W 41.5V
  • 240W 41.5V
  • 360W 41.5V
  • 360W UART 41.5V
  • 600W 41.5V
  • 600W UART 41.5V